Quartz Glass Grid Calibration Plate

  • Price:

    Negotiable

  • minimum:

  • Total supply:

  • Delivery term:

    The date of payment from buyers deliver within days

  • seat:

    Zhejiang

  • Validity to:

    Long-term effective

  • Last update:

    2022-09-30 13:29

  • Browse the number:

    454

Send an inquiries

Company Profile

Ningbo Zhixing Optical Technology Co., Ltd

By certification [File Integrity]

Contact:zhixingheyi(Mr.)  

Email:

Telephone:

Phone:

Area:Zhejiang

Address:Zhejiang

Website:http://www.calibplate-zhixing.com/ http://zhixingheyi.wfyydg.com/

Product details


Feature:


model

Width * Length

Number of lattices

Square side length

Distance

texture of material

accuracy

C6

6.0*4.5mm

12*9

0.5*0.5mm

Glass/ceramic

±0.001mm

C12

12*9.0mm

12*9

1.0*1.0mm

Glass/ceramic

±0.001mm

C18

18*13.5mm

12*9

1.5*1.5mm

Glass/ceramic

±0.001mm

C24

24*18.0mm

12*9

2.0*2.0mm

Glass/ceramic

±0.001mm

C36

36*27.0mm

12*9

3.0*3.0mm

Glass/ceramic

±0.001mm

C48

48*36.0mm

12*9

4.0*4.0mm

Glass/ceramic

±0.001mm

C60

60*45.0mm

12*9

5.0*5.0mm

Glass/ceramic

±0.001mm

C84

84*63.0mm

12*9

7.0*7.0mm

Glass/ceramic

±0.001mm

C108

108*81.0mm

12*9

9.0*9.0mm

Glass/ceramic

±0.001mm

C180

180*165.0mm

12*11

15.0*15.0mm

Glass/ceramic

±0.001mm

Only some products are shown in the table, if you need other products, you can consult customer service


Chrome film exhibit


Physical display of Quartz Glass square calibration plate

The camera calibration technology requires accurate camera intrinsic and extrinsic parameters as the

 input and prerequisite for the reconstruction algorithm. The most popular camera calibration

 algorithm is proposed by Tsai in 1987 [Tsai1987]. The Tsai method uses a non-coplanar dedicated

 algorithm. The identified 3D calibration object is calibrated to provide the correspondence between

 the image point and its corresponding 3D space point and the calibration parameter is calculated.

 Another practical approach was proposed by Zhang in 1999 [Bouguet2007], which requires at least

 two different views of a planar calibration pattern for calibration. Both methods are effectively

 implemented by Caltech's camera calibration tool and have been integrated into Intel's vision

 algorithm library OpenCV [OpenCV2004]. Through the calibration algorithm, the projection matrix of

 the camera can be calculated and the 3D measurement information of the scene can be provided.

 Similar transformation-level metric reconstruction can be achieved without given absolute translation,

 rotation, and scaling parameters of the real scene.




Exhibition photos