Negotiable
The date of payment from buyers deliver within days
Anhui
Long-term effective
2017-10-03 12:24
111
Company Profile
ANHUI WNK ELECTRONIC ENGINEERING CO., LTD.By certification [File Integrity]
Contact:Ms. Lily Huang(Mr.)
Email:
Telephone:
Phone:
Area:Anhui
Address:Anhui
Website: http://wnksensor.wfyydg.com/
Measuring media | liquid, gas and steam | ||
Measuring range | -270~800 ºC (PT100 thermal resistor) | ||
0~1300ºC, (Thermocouple K) | |||
Input | Thermocouple, RTD, MV, Resistive sensor | ||
Power supply range | 9~45V (9~24V, Ex) | ||
Output signal | 4~20mA/Hart/Profibus PA | ||
Digital Accuracy | ±0.01ºC, PT100 input | ||
Internal cold end compensation error | <0.25ºC±0.1%/10ºC | ||
Temperature drift | ±0.05%/10ºCfull scale range | ||
0.1% between-10°C to 60°C | |||
Effect of power supply on range | <0.005%/V full-scale range | ||
Long term drift | <0.1/year | ||
Ambient temperature | Ambient temperature | Storage temperature | |
T4 | Safe operation(T6) | ||
-40...85ºC | -40...60ºC | -40...95ºC | |
Protection Class | IP66/67 | ||
Relative humidity | ≤98%, condensation allowed | ||
Electromagnetic compatibility | Accordance with EN 61 326 |
Model | Product details | ||||
WNK6T | Smart temperature transmitter | ||||
Code | Approvals | ||||
A | For non explosion-proof areas | ||||
1 | ATEX II 1/2G EExia II CT6 | ||||
2 | ATEX II 1/2G EExia II CT6,overflow protection WHG | ||||
3 | ATEX II 1/2D | ||||
4 | ATEX II 1/3GD EExia II CT6 | ||||
5 | ATEX II 1/3D | ||||
6 | ATEX II 2G EEx d II T6 | ||||
7 | ATEX II 3G EEx nA II CT6 | ||||
For other approvals or more information, please contact with us | |||||
Code | Communication, Display, Operation | ||||
A | 4...20mA HART,LCD,operation outside | ||||
B | 4...20mA HART,LCD,operation inside | ||||
C | 4...20mA HART | ||||
M | PROFIBUS PA,LCD,operation outside | ||||
N | PROFIBUS PA,LCD,operation inside | ||||
O | PROFIBUS PA | ||||
P | FF,LCD,operation outside | ||||
Q | FF,LCD,operation inside | ||||
R | FF | ||||
Code | Housing; Cable entry; Protection | ||||
A | Aluminum14,M20×1.5,IP66/67/NEMA 6P | ||||
B | Aluminum14,G1/2,IP66/67/NEMA 6P | ||||
C | Aluminum14,1/2NPT,IP66/67/NEMA 6P | ||||
Code | Type of the transmitter connecting with sensor | ||||
X1 | Integral type | ||||
X2 | Split type | ||||
For integral type, it need to choose the connection additional option | |||||
Code | Input type, Measurement range | Code | Input type, Measurement range | ||
OA | Ohm,0~100Ω | RA | Thermocouple ,S | ||
OB | Ohm,0~260Ω | RB | Thermocouple,R | ||
OC | Ohm,0~390Ω | RC | Thermocouple,B | ||
OD | Ohm,0~3900Ω | RD | Thermocouple,K | ||
OE | Ohm,PT100 | RE | Thermocouple,N | ||
OF | Ohm,PT1000 | RF | Thermocouple,E | ||
OG | Ohm,CU50 | RG | Thermocouple,J | ||
OH | Ohm,CU100 | RH | Thermocouple,T | ||
DA | Voltage,-20~20mV | ||||
DB | Voltage,-50~50mV | ||||
DC | Voltage,-75~75mV | ||||
DD | Voltage,-750~750mV | ||||
Code | Standardization,unit | ||||
1 | Standardization:rated range,°C | ||||
2 | Standardization:rated range,°F | ||||
3 | Standardization:rated range,°R | ||||
Code | Option | ||||
A | No | ||||
M | Mounting bracket for wall | ||||
U | Mounting bracket for pipe | ||||
Code | Additional option for intergral type(interface: transmitter to sensor) | ||||
F1 | M10×1 | F4 | M20×1.5 | ||
F2 | M12×1 | F5 | M24×1.5 | ||
F3 | M18×1.5 | F6 | Per customer requirement | ||
Typical model#: WNK6T AAA X2RD 1U |